Kuma Stoves
Hayden, ID. USA
MODEL:
ARCTIC
(AR-7, AR-8, AR-10)
Fuel-oil stove
User Manual for:
-Installation
-Operation
-Servicing
This manual contains information necessary for the safe installation and op-
eration of your Kuma Arctic either in residential or mobile homes. While most
anyone can install their oil stove, it is recommended that the installation be done
by a qualified installer familiar with fuel oil stoves, preferably an NFI (National
Fireplace Institute) Certified expert. We recommend contacting local building or
fire officials in your area regarding restrictions and installation inspection require-
ments. Please read this entire manual before attempting installation or operation
of this appliance. Improper installation or operation of this oil stove can result in
bodily or property damage.
*SAVE THESE INSTRUCTIONS*
Rev. 9/05
Przeglądanie stron 0
1 2 3 4 5 6 ... 10 11

Podsumowanie treści

Strona 1 - Kuma Stoves

Kuma Stoves Hayden, ID. USA MODEL: ARCTIC (AR-7, AR-8, AR-10) Fuel-oil stove User Manual for: -Installation -Oper

Strona 2 - SECTION 1

5. -Carburetor out of adjustment (decrease high-fire screw). -Cold flue. -Flame set too high (flame impinging on baffle too much)

Strona 3 - (Part# ARCS)

SECTION 7 Limited Lifetime Warranty Your Kuma Arctic is warranted against defects in materials or workmanship according to the following:

Strona 4 - SECTION 2

CONTENTS Section 1– Stove placement, air requirements, Convection shell installation Instructions, and clearan

Strona 5 - SECTION 3

A storm or dryer type vent with a screen is adequate. For your convenience, an outside air kit (part # 4OAVK) is available through your dealer. I

Strona 6 - SECTION 4

SECTION 2 The flue and flue connections Do not connect this unit to a flue servicing another appliance. It is of utmost importance that th

Strona 7

SECTION 3 Fuel tank installation and fuel line connections OIL: Your Kuma Arctic comes with a carburetor set for an average of a 2.35 cc. viscosi

Strona 8 - Servicing

SECTION 4 Lighting and carburetor adjustments PRE-LIGHTING CHECKS: The installation should be inspected to ensure that the work is co

Strona 9 - Trouble-shooting guide

6. When oil is lit, replace the catalyst/ top burn ring and shut the door (a slightly cracked door is helpful for a sho

Strona 10

The carburetor on your Arctic has a main float valve internally to regulate the oil level in the stove. It also has a separate, second safety float

Strona 11 - Limited Lifetime Warranty

SECTION 6 Trouble-shooting guide CONDITION: 1. Oil present in burner with the carburetor in “off” position. 2. No oil in burner